Density Keyword
|
| Description |
By default, population and other analysis procedures use the SCF density. The generalized densities for the MP2, MP3, MP4(SDQ), QCISD, CCD, CID and CISD methods are available. These are based on the Z-Vector [92,217,218,219], and hence yield multipole moments which are the correct analytical derivatives of the energy. The unrelaxed densities at second order (not the same as MP2) and CI can also be used but are not recommended.
The options of the Density keyword select which density to analyze. The Density keyword without an option is equivalent to Density=Current.
| Options |
Current
Use the density matrix for the current method.
This is the default when no option is given to Density.
All
Use all available densities. This is allowed for
population analysis but not for electrostatics or density evaluation. Note that
this option does not produce densities for all of the excited states in a
CI-Singles calculation, only the density for the state of interest (see the
examples below for a method for doing the former).
HF
Use the SCF density. SCF is a synonym for
HF.
MP2
Use the generalized density corresponding to the
second-order energy.
Transition=N[,M]
Use the CIS
transition density between state M and state N. M defaults
to 0, which corresponds to the ground state.
AllTransition
Use all available CIS transition
densities.
CI
Use the generalized density corresponding to the CI
energy.
QCI
Use the generalized density corresponding to the
QCI (or coupled cluster) energy. CC is a synonym for QCI.
RhoCI
Use the one-particle density computed using the
CI wavefunction for state N. This is not the same as the CI
density [219], and its use is discouraged! Chapter 9
of Exploring Chemistry with Electronic Structure Methods discusses this
issue [304].
Rho2
Use the density correct to second-order in
Møller-Plesset theory. This is not the same as the MP2 density!
[219]
CIS=N
Use the total unrelaxed CIS density for
state N. Note that this is not the same as the density resulting
from CIS(Root=N,...) Density=Current, which is to
be preferred [219].
Checkpoint
Recover the density from the checkpoint file
for analysis. Implies Guess=Only CheckBasis: the calculation does not
recompute new integrals, SCF, and so on, and retrieves the basis set from the
checkpoint file.
| Related Keywords |
| Examples |
The following route section specifies a CI-Singles calculation which predicts the first six excited states of the molecule under investigation. The population and other analyses will use the CIS density corresponding to the lowest excited state:
%Chk=benzene # CIS(NStates=6)/6-31+G(d,p) Density=Current Pop=CHelpG
The following route section may be used to rerun the post-CIS analyses for the other excited states:
%Chk=benzene # CIS(Read,Root=N) Density=Current Pop=CHelpG # Guess=Read Geom=Check
This route picks up the converged CIS and CIS wavefunction from the checkpoint file, and performs the necessary CPHF calculation to produce the relaxed density for state N, which is then used in the population and other analyses.